ACCESSORIES FOR SYSTEM ENHANCEMENTS
S5050 RELAY/EVENT MEMORY MODULE (REMM)
The S5050 relay/event memory module is used for expanding relay outputs (5 outputs per module)
and event memory (250 events per module). Maximum of two S5050 modules per S5832 control panel.
Features
• Five relays - wet or dry contacts set by switch.
• 250 Event memory (date and time stamped).
• Easily connects on system data bus.
• Optional wall and cover tamper switch.
• Mounts in the panel enclosure or remotely up to 305 m away - saves wiring and labour costs.
• Over 70 programmable functions with individual relay control.
Specifications
Voltage : 9.5 ~ 14.5 Vdc
Cable : 4 core (305 m)
Current draw : 20 mA (all relays non-energised)
100 mA (all relays energised, 16 mA / relay)
100 mA (limited auxiliary output)
200 mA (all relays and auxiliary terminal)
Contacts rated : 1 A @ 12 Vdc
60 VA (max. switching power)
Operating temperature : 0° ~ 50°C; relative humidity up to 95% non-condensing
Housing : off-white, polycarbonate
Dimensions : 111 x 81 x 35 mm (HxWxD)
S5052 TAMPER KIT
Combined wall- and cabinet door tamper switch.
S5053 LOAD SHED MODULE
The S5053 load shed module is used for disconnecting the battery from the S5832 control panel
during a low battery condition to prevent deep discharge of the battery.
Features
• Disconnects the battery from the control panel during extended AC failure to prevent deep discharge.
• Installs in seconds.
• Double back tape allows easy mounting anywhere inside the enclosure.
Specifications
Cut-out voltage : 9.8 Vdc
Max. current : 5 A
Input leads (from battery) : 190 mm
Output leads (to panel) : 75 mm
Operating temperature : 0° ~ 50°C; relative humidity up to 95% non-condensing
Dimensions : 65 x 32 x 29 mm (HxWxD)
S5054 BATTERY CONNECTION CABLE
The S5054 is used to connect two 7Ah batteries in parallel to the S5832 control panel.
S5058 ZONE EXPANSION MODULE (ZEM)
The S5058 module is used for expanding the number of zones (8 zones per module). Maximum of
three S5058 modules per S5832 control panel.
Features
• Each model adds 8 hardwire zones to the Sierra S8832 control panel.
• Zone inputs can be configured for four state operation: normal, trouble, tamper and faulted.
• Adjustable zone response time controlled by the panel (for group of 8 zones).
• Easily connects on system data bus.
• Optional wall and cover tamper switch.
• Mounts in the panel enclosure or remotely up to 305 m away - saves wiring and labour costs.
Specifications
Voltage : 9.5 ~ 14.5 Vdc
Cable : 4 core (305 m)
Current draw : 30 mA (main PCB only)
300 mA (limited auxiliary outputs)
330 mA (PCB and outputs)
Operating temperature : 0° ~ 50°C; relative humidity up to 95% non-condensing
Housing : off-white, polycarbonate
Dimensions : 111 x 81 x 35 mm (HxWxD)